Clean and free the roof surface of any debris and then dry the surface using a cloth. If you happen to have a current coating on the surface, check for adhesion. Consider removing loose coating, repairing, cleaning and then checking the area. Remember to use Energy Guard without thinning it because it is sold ready for use. Containers should not be left open except for a short period of time. You must also ensure that you check for any existing coating adhesion before opening Energy Guard. For application, you will require a brush preferably a bristle brush (synthetic) or a short nap roller. You can also use a good airless sprayer with a 0.031 or 0.027 tip to apply the coatings at (3000 psi/1gpm). You will also need water for cleaning up when you are done.
R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties.
These coatings are emulsified asphalt and consist of asphalt particles dispersed in water; they utilize clay as the emulsifying component. These coatings also contain many types of organic and/or inorganic fibers and fillers to provide extra strength to the coating. These coatings are available in black, brown, or as a reflective coating when titanium dioxide or aluminum pigments are added.
Note:  A board foot is defined as a 12" x 12" square at 1" thick. Actual output can be affected by a number of factors including temperature and humidity. The theoretical yield has become an industry standard for identifying certain sizes of two component kits. Theoretical yield calculations are performed in perfect laboratory conditions, without taking into account the loss of blowing agent or the variations in application methods and types. 

How Much Does It Cost For Spray Foam Insulation


The United States has adapted to using sprayfoam insulation and a new technology called Wall Injection to retrofit existing wall construction by drilling small holes between wall studs in the structures framing and filling the void with a less aggressive expanding water based foam. This allows existing home and business owners to conserve energy by creating a thermal envelope in their existing structure.


In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.
Heat which is created elsewhere that is transported by means of a fluid, such as water or in our case air. Spray foam insulation's most important attribute is the ability to air seal creating a custom airtight envelope within the building structure. The added benefit to air sealing is the ability to block convective heat transfer from interior to exterior during heating months and vice versa during cooling months, as the heat cannot escape through gaps in the buildings envelope without the aid of air movement from infiltration as a means of transport. https://www.youtube.com/v/ggLAUsiuI_o&feature=share
I have to insulate my walls at the end of this week. That does not give me time to procure slow-rise foam, so my stud cavities will be filled with foam before I'm ready to fill the corner voids. I will not be able to drill straight through the corner studs. Instead, I will have to remove material where the studs meet. What sort of tool do you envisioning me holding while I create space to pump foam into my 1972 corner voids?
Get the Power to Seal & Insulate Perfectly in Just 5 Minutes. The Foam it Green Promise: 1>Simpler, Easier, Faster Spray Foam 2>No Special Skills or Know How 3>Professional Results or Better Saves You Time, Money and Hassles. Delivers to your door, ready to use. Just follow the simple instructions. Saves Energy with High R-value Closed Cell Foam. R-Value of 7 in Just 1 Inch. Provides a seamless air barrier in 1 step. This Kit Provides Approx. 602 Square Feet at 1” thickness of cured foam. Class I E-84 Fire-Retardant Foam that meets building code specs. This Anti-Microbial Formula passed the stringent ASTM G-21 test for preventing mold growth on the surface of the foam. Includes everything you need to complete your project. Weighs 120 lbs, including steel canisters pressured with nitrogen. Orders with multiple kits on it may ship via LTL instead of UPS. The LTL carrier calls to arrange a convenient delivery time. Usually Ships Same Business Day. See Manufacturer for returns and warranty policy.

Spray Foam Metal Building


While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, ocSPF is not a vapour barrier. When installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications.

Spray Foam Basement Ceiling


Open cell spray foam consists of cells that do not completely seal themselves. This makes for a softer and less dense final product. Closed cell foam cells are completely sealed and closed compressed together, creating a denser and firmer final product. This also gives closed cell foam a higher R-value (measured unit of thermal resistance). These differences also affect the cost difference between the two types of insulation. http://kvsprayfoam.com/images/open-cell-wall.jpg
Acrylic coatings are typically applied in two coats, with the second running perpendicular to the first. 1 gallon per 100 square feet is a good estimate for these coatings, as they do not need to be applied nearly as thick as many other coatings. These coatings can be sprayed or roll-applied. Acrylic coatings generally require a re-coat within 2-3 years of application.

Spray Foam Roof Insulation

×