These coatings contain various types of acrylic polymer, and are typically formulated to help extend the coating’s life and improve durability. Acrylic coatings are available in a number of colors but are most commonly used as white reflective coatings. Thanks to its durability and low cost, many contractors and facility managers believe this to be the best roof coating. http://kvsprayfoam.com/images/KV-Spray-Foam-Denver.jpg
One of the key differentiators between traditional insulation materials and spray foam insulation is the latter’s ability to insulate and air seal. Foam insulation provides an air barrier to wherever it is applied to help mitigate air leakage from the building. Air sealing the building envelope with sprayed-in foam insulation also helps address moisture ingress to reduce the risk of mold and mildew growth as well as the formation of ice dams in colder climate zones during the winter months.  When you compare foam insulation with traditional fiberglass insulation and cellulose insulation, sprayed insulation minimizes air infiltration, it assists in limiting moisture vapor from entering and escaping the home, which in turn reduces the load on heating and cooling systems. Below is a video that compares fiberglass, cellulose and open-cell spray foam in terms of insulating and air sealing value.
We love the Heng’s rubber roof coating because it is versatile enough to work on the RV roof and protects it from the elements longer than other products do. Plus, it is useful enough to be used in sealing seams and tears. Versatility does matter when shopping around for an RV roof coating. It ensures more uses, meaning more value for the money. That said we don’t need to buy a separate product to perform the tasks.

How Much Is Open Cell Spray Foam Insulation


If you cut the nails holding one of the corner studs to the bottom plate and the top plate with a Sawzall, you can use a flat bar (or a flat bar plus a wrecking bar) to pull the stud off the sheathing nails. Either re-use the stud, or buy a new stud, and install the stud with toenails as shown in the link I provided in Comment #51 (this link: Outside corner detail).
The problem you saw with the closed cell foam pulling away like that is due to the heat of the foam was to hot. It was actually curing out and making foam before it could adhere to the wood. The installer wasn't reading his foam correctly. He should of stopped and turned down the heat on his hose temp. Also installers have to be aware that as the sun rises and the temp in attics rises the subtrates get hotter as well. This will cause the installer to adjust his heat when installing the foam as the temp changes thru out the day.  
Open cell spray foam consists of cells that do not completely seal themselves. This makes for a softer and less dense final product. Closed cell foam cells are completely sealed and closed compressed together, creating a denser and firmer final product. This also gives closed cell foam a higher R-value (measured unit of thermal resistance). These differences also affect the cost difference between the two types of insulation. https://m.youtube.com/v/ggLAUsiuI_o

Air infiltration and exfiltration within a home contributes to almost 99% of moisture migration. Restricting air movement stops moisture accumulation so that the possibility of mold growth is less likely. Combined with a properly sized HVAC system, spray foam insulation helps control the indoor humidity levels to minimize moisture and condensation. Reducing moisture and controlling humidity can also add years to the life expectancy of a home, plus contribute to a healthier indoor environment. Finally, it also deters pests, making it difficult for them to nest.
Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting.
Wallice Foam did a fantastic job on our new home and my little she shed. While in the process of backing in our extremely difficult driveway with their unit our mailbox was accidentally knocked over, and they were there within three hours that same day and brought a crew to repair and set back up our mailbox, we greatly appreciate there honesty and their willingness to repair our mailbox and so promptly. We would highly recommend this company for any foam insulation needs you may have. The *****’s
One of the high-tech insulation products being utilized these days is a foam-spray product called "Icynene," which is a foam that starts as two liquid components (a and b, if you will) that are heated up and sent through two hoses and meet at a tip of a gun where the magic begins. This is a thin film that expands to 100 times its volume in eight seconds, when it's permanently set up.

once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly.
R-value is the term given to thermal resistance to heat flow. The higher the R-value of an insulation product, the more effective the insulation properties. Spray polyurethane foam comes in a range of densities and cel structure. Low density foams are referred to as Open Cel SPF while higher density foams are referred to as Closed Cel foam. 1.8-2 pound polyurethane foam has the highest R-value of readily available spray foam insulation used in homes and buildings.[4]
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).
The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.  

If you don't have the patience to slowly fill the void with spray foam through holes drilled in one of the studs, you could (if you were an experienced carpenter) use a Sawzall to remove one of the studs and re-frame the corner as a two-stud corner. Then you could either insulate the void with a fiberglass batt or simply present the two-stud corner to the spray-foam contractor as an accessible corner. http://youtube.com/watch?v=ggLAUsiuI_o&app=desktop

The insulation at eaves level will leave your loft area comfortable for use and free from condensation. By installing the insulation at rafter level, it keeps the loft void warmer and prevents condensation build-up, which can otherwise occur when increasing insulation at ceiling level. The warmer, drier, cleaner roof space eliminates the risk of pipes and tanks freezing.
Seal It Insulation Systems (headquartered out of Brunswick, Maine) performs residential home insulation, commercial spray foam insulation projects, and will also handle your industrial building needs. We use only the highest performing, industry tested foam products, with a primary focus on indoor air quality and temperature. While every insulation project is likely to give you a considerable return on your financial investment through gained energy efficiencies, it’s also likely to have a dramatic impact on your level of comfort. We work with homeowners, architects, contractors and facility managers to design these high-performing insulation systems, and to solve pre-existing performance issues in your building like ice damming, freezing pipes, high heating bills, mold/mildew conditions, and drafty, uncomfortable living spaces.
Heatlok®, is a high-performance, versatile spray foam insulation designed for residential construction. Its unique formula incorporates recycled plastic bottles and renewable oils to create high-performance, closed-cell spray foam insulation. This polyurethane insulation combines multiple control layers into a single application, saving homeowners both time and money in construction costs. With our innovative technology, Heatlok is developed with 14 % renewable and recycled content, and is the ideal choice for residential construction.

Spray Foam Crawl Space


I did a LOT of prep before using this product. Cleaned, vacuumed, installed additional insulation etc etc etc. This spray foam was easy to work with, and did it's job as it was supposed to. If you are curious, this kit was purchased because - every "foam insulation company" I contacted either did not call back (due to no interest) OR this was too small of a job. That is why I went DIY on this one, that and: I was advised by one of these companies that they have a minimum $2k job because ... (insert your answer here, but I will choose that everyone needs to eat).
To see if ShippingPass is right for you, try a 30-day free trial. Also, with ShippingPass, there is no need to worry about commitment. If you decide you want to discontinue the service, you can cancel your subscription at any time. No matter what your shipping needs, Walmart's got you covered. Sign up for ShippingPass so you can shop more, save money and live better.
Henry 587 Dura-Brite White Elastomeric Roof Coating is Henry 587 Dura-Brite White Elastomeric Roof Coating is a premium high solids formula offering better weather protection solar reflectivity and longevity than economy grade reflective roof coatings. Cured coating forms a permeable membrane which prevents liquid infiltration but allows moisture vapor to vent or breathe out of underlying substrate. Recommended ...  More + Product Details Close

Spray Foam Polyurethane


Spray foam insulation works by sealing the building envelope to stop conditioned air from escaping and prevent unwanted outside air from entering your home. It allows efficient use of your HVAC system and helps regulate the temperature fluctuations and humidity in your home. It's a lightweight, durable, and versatile insulation solution boasting the industry’s strongest performance in energy efficiency and energy cost savings.
Henry 587 Dura-Brite White Elastomeric Roof Coating is Henry 587 Dura-Brite White Elastomeric Roof Coating is a premium high solids formula offering better weather protection solar reflectivity and longevity than economy grade reflective roof coatings. Cured coating forms a permeable membrane which prevents liquid infiltration but allows moisture vapor to vent or breathe out of underlying substrate. Recommended ...  More + Product Details Close
Ames® Roof Coatings are premium elastomeric coatings that seal out moisture, renew old surfaces and even save energy. We have products specifically formulated for all types of roofs including; Wood, Tar, Metal, Rolled Roofing, EPDM Rubber, Foam and many other surfaces. Ames’ coatings form a waterproof seal to preserve and protect your roof. Our white roof coatings reflect sunlight, substantially reducing roof temperatures. Ames® products are environmentally friendly, waterbase, non-toxic, VOC-free and water cleanup.
Was hesitant to buy this product because of some of the reviews but glad I did. It does just what it says and we even got the square footage out of it. You just need to read ALL the directions first and it wouldn't hurt to read some of the helpful hints in some of the reviews. It does only cover 1 inch at 600 square feet and is extremely easy to apply. Very satisfied customer!

Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells.[5] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch.[5] In comparison, blown fiberglass typically has an R-Value of only R-3 to R-4 per inch.[6]

How Much Spray Foam Cost


FROTH-PAK Foam Sealant is a two-component quick-cure polyurethane FROTH-PAK Foam Sealant is a two-component quick-cure polyurethane foam that fills cavities penetrations cracks and expansion joints. FROTH-PAK foam sealant can also be used as a sealant and void fill in many roofing applications. FROTH-PAK is chemically cured foam which significantly reduces curing time. FROTH-PAK dispenses expands and becomes tack ...  More + Product Details Close
We have a 1950's ranch in Atlanta and are interviewing foam contractors to spray open cell under the roof, with an "ankle wall" out towards the eaves to seal the attic. My wife and daughters are chemically sensitive, so I'm trying to figure out how to minimize the fumes coming into the house. Additionally, at least one contractor has offered (for > $900) to remove our existing rock wool & R-13 fibreglass from the attic floor to "increase cross-ventilation into the attic". Seems to me I can't both minimize fumes AND increase cross-ventilation. They also offered to spray a fire-retardant on for >$600. Would ventilation during installation help any or woud the retardant seal off the foam and help that way? Thanks...

The United States has adapted to using sprayfoam insulation and a new technology called Wall Injection to retrofit existing wall construction by drilling small holes between wall studs in the structures framing and filling the void with a less aggressive expanding water based foam. This allows existing home and business owners to conserve energy by creating a thermal envelope in their existing structure.

Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 
The insulation at eaves level will leave your loft area comfortable for use and free from condensation. By installing the insulation at rafter level, it keeps the loft void warmer and prevents condensation build-up, which can otherwise occur when increasing insulation at ceiling level. The warmer, drier, cleaner roof space eliminates the risk of pipes and tanks freezing.
Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.).
The blowing agent is captured within the cells which contributes to highly efficient insulating properties. In addition, closed-cell foam provides an inherent air barrier with low moisture vapor permeability, and excellent resistance to water. The density for closed-cell spray foam is approximately two pounds per cubic foot. The medium density foam provides sheer and racking strength to wall assemblies in building applications.
The insulation at eaves level will leave your loft area comfortable for use and free from condensation. By installing the insulation at rafter level, it keeps the loft void warmer and prevents condensation build-up, which can otherwise occur when increasing insulation at ceiling level. The warmer, drier, cleaner roof space eliminates the risk of pipes and tanks freezing.
Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.
If you don't have the patience to slowly fill the void with spray foam through holes drilled in one of the studs, you could (if you were an experienced carpenter) use a Sawzall to remove one of the studs and re-frame the corner as a two-stud corner. Then you could either insulate the void with a fiberglass batt or simply present the two-stud corner to the spray-foam contractor as an accessible corner. http://youtube.com/watch?v=ggLAUsiuI_o&app=desktop
In the case you have above the installer wasn't reading his foam. They must be trained to do that as they spray. Temps and conditions are constantly changing thru out the day. Either he wasn't properly trained or if he was,he wasn't doing his job! This is a serious problem with people jumping in to the foam business. A lot of homeowners and builders are looking the best price and end up with someone who doesn't know what they are doing. Hope this info helps. Foam insulation is a great product. It just has to be done right by someone who knows what they are doing.

Where To Buy Liquid Spray Foam

×