These coatings contain various types of acrylic polymer, and are typically formulated to help extend the coating’s life and improve durability. Acrylic coatings are available in a number of colors but are most commonly used as white reflective coatings. Thanks to its durability and low cost, many contractors and facility managers believe this to be the best roof coating. http://kvsprayfoam.com/images/KV-Spray-Foam-Denver.jpg
The insulation at eaves level will leave your loft area comfortable for use and free from condensation. By installing the insulation at rafter level, it keeps the loft void warmer and prevents condensation build-up, which can otherwise occur when increasing insulation at ceiling level. The warmer, drier, cleaner roof space eliminates the risk of pipes and tanks freezing.

As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine. https://www.youtube.com/watch?v=ggLAUsiuI_o&app=m
As mentioned above elastomeric coatings can be used to fix almost all types of roofs. Examples of common roof types that will work well with elastomeric coatings include; wood, polyurethane foam, single-ply roofing, modified bitumen, metal roofs, concrete and built-up roofing. If you aren't sure your roof type will work well elastomeric coatings, do not hesitate to contact us. Our experts are always willing to help.
Most flat roofs are not perfectly sloped, causing water to puddle in some areas, in particular around the drains and scuppers. Many roof coatings are not rated or warranted for "ponding water", and thus might fail pre-maturely if exposed to standing water over long periods of time. Serious consideration should be given to the performance and limitations of the coating being selected. Some manufacturers will warranty their coatings including ponding water. Typically, manufacturers for acrylic roof coatings do not include warranties for ponding water, while some polyurethane and silicone roof coatings manufacturers will.
a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer.
Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else. 

Spray Foam On Roof Deck


Water-based acrylic coatings have more than 30 years of proven performance over a wide range of substrates. It is the coating of choice for metal roofs since it is highly reflective, can be easily tinted and is not extremely slippery when damp. When used with our rust primer, even rusted roofs can be saved. TIP: If you have a metal roof or a low slope roof that doesn't pond water, consider acrylic coatings. https://www.youtube.com/v/ggLAUsiuI_o&feature=youtu.be
Heat which is created elsewhere that is transported by means of a fluid, such as water or in our case air. Spray foam insulation's most important attribute is the ability to air seal creating a custom airtight envelope within the building structure. The added benefit to air sealing is the ability to block convective heat transfer from interior to exterior during heating months and vice versa during cooling months, as the heat cannot escape through gaps in the buildings envelope without the aid of air movement from infiltration as a means of transport. https://www.youtube.com/v/ggLAUsiuI_o&feature=share

Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.
With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care.
A unique new event spotlighting the latest design & building processes, products and emerging technologies. This interactive three-day conference & expo is designed to inform and inspire today’s entire building team — innovative and influential architects, engineers, contractors, facility managers, owners and more. Educational sessions will include six separate tracks focused on plumbing, HVACR/mechanical systems, flooring, building envelope, roofing and general contracting.

Where Can I Buy Polyethylene Foam Spray

×